Seiko Cal. V117 Service Manual

Browse online or download Service Manual for Kitchen scales Seiko Cal. V117. Seiko Cal. V117 Service manual User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 52
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
75591
DI-80
SS
SS
ee
ee
rr
rr
vv
vv
ii
ii
cc
cc
ee
ee
MM
MM
aa
aa
nn
nn
uu
uu
aa
aa
ll
ll
When Accuracy Counts
II
II
nn
nn
dd
dd
ii
ii
cc
cc
aa
aa
tt
tt
oo
oo
rr
rr
Page view 0
1 2 3 4 5 6 ... 51 52

Summary of Contents

Page 1 - When Accuracy Counts

75591 DI-80 SSSSeeeerrrrvvvviiiicccceeee MMMMaaaannnnuuuuaaaallllWhen Accuracy CountsIIIInnnnddddiiiiccccaaaattttoooorrrr

Page 2

DI 80 SOFTWARE SETTING 8 6.3 SPECIFICATION LIST (REVISION 10) 6.3.1 DI-80 SOFTWARE HISTORY Revision No. Modification Details Software Ver

Page 3

DI 80 SOFTWARE SETTING 9 6.3.2 CUSTOMER SPECIFICATION [REZERO] + [1][4][1] SPEC NO. BIT 3 BIT 2 BIT 1 BIT 0 0 U1 Version 0 : No

Page 4

DI 80 SOFTWARE SETTING 10 SPEC NO. BIT 3 BIT 2 BIT 1 BIT 0 13 Build-in Printer 0 : No 1 : Yes Auto Print 0 : No 1 : Yes Date and Ti

Page 5 - + 2

DI 80 SOFTWARE SETTING 11 SPEC NO. BIT 3 BIT 2 BIT 1 BIT 0 58 Analogue Output 1 : Yes 0 : No Negative Weight Operation *5 1 : Yes 0

Page 6

DI 80 SOFTWARE SETTING 12 6.3.3 WEIGHT AND MEASURE SPECIFICATION [REZERO] + [1][4][2] (Span Switch must be turned ON when accessing this mode

Page 7

DI 80 SOFTWARE SETTING 13 SPEC NO. BIT 3 BIT 2 BIT 1 BIT 0 35 Not Used Load Cell Type (Scale 2) 0 : For standard / normal load cell

Page 8

DI 80 CALIBRATION 14 7. CALIBRATION (Version 0.42 and above) 7.1 ZERO AND SPAN CALIBRATION Please turn on the SPAN SWITCH before proceed. (If S

Page 9

DI 80 CALIBRATION 15 7.2 INTERNAL COUNT / AD COUNT DISPLAY OPERATION DISPLAY REMARKS Main(W) Sub-1(UW) Sub-2(Q) [REZERO] 88888 88888

Page 10

DI 80 FLASH DOWNLOADING 16 8 FLASH DOWNLOADING There are 2 types of downloading: i) User Mode Downloading -- this mode of flash downloading i

Page 11 - DI 80 SOFTWARE SETTING

DI 80 FLASH DOWNLOADING 17 2) While pressing [REZERO] + [#] button together, press the [ON/OFF] button. The following will be shown on the indica

Page 13

DI 80 FLASH DOWNLOADING 18 6) If software is being loaded into DI 80 previously, it will be erased. The following will be shown on the monitor :

Page 14

DI 80 FLASH DOWNLOADING 19 8.1.2 BOOT MODE Downloading 1) Switch the option switch to BOOT mode on the DI 80 and turn “On” the power only. 2)

Page 15

DI 80 FLASH DOWNLOADING 20 4) Activate the download by clicking on the <Start Download> icon. The program will run automatically by searchi

Page 16

DI 80 PC / PRINTER CONNECTION 219. PC / PRINTER CONNECTION 9.1 GENERAL SPECIFICATION Baud rate : 1200 / 2400 / 4800 / 9600 bps Data lengt

Page 17

DI 80 PC / PRINTER CONNECTION 229.3 DATA i) ID code vi) Tare weight xi) Inventory ii) Set point vii) Quantity xii)

Page 18

DI 80 PC / PRINTER CONNECTION 239.5 WIRE CONFIGURATION 9 PIN D-SUB CONNECTOR 25 PIN D-SUB

Page 19

DI 80 PC / PRINTER CONNECTION 249.6 PC / PRINTER RS232C CONNECTION SPEC SETTING Setting on DI 80 under [Re-Zero]+[141] : If using SIO 1 : RS2

Page 20

DI 80 PC / PRINTER CONNECTION 259.7 BUILT-IN PRINTER Setting on DI 80 under Re-Zero+[141] : Built-in Printer Set SPEC 13 Bit 3 to 1 Line Ther

Page 21

DI 80 BARCODE SCANNER CONNECTION 26 10. BARCODE SCANNER CONNECTION DI 80 can support these barcode scanners : RS232C TYPE Pen scanner - ZEBE

Page 22

DI 80 BARCODE SCANNER CONNECTION 27 The barcode scanner can be use in the following operation : 10.4.1 OPERATION Mode : UNIT WEIGHT ID CODE

Page 23

DI 80 GENERAL SPECIFICATION 11. GENERAL SPECIFICATION Model : DI 80 Dimension : 255 (L) X 240 (W) X 146 (H) Number Of Loadc

Page 24

DI 80 BARCODE SCANNER CONNECTION 28 10.5 BARCODE SCANNER CONNECTION SPEC SETTING If using SIO 1 : SPEC No. 8 Bit 0, 1 and 2 Type Of Devices *

Page 25

DI 80 BARCODE SCANNER CONNECTION 29 If using SIO 3 : SPEC No. 54 Bit 0, 1 and 2 Type Of Devices* 0 0 0 Barcode scanner 0 1 0 LP 2622 1

Page 26

DI 80 SET POINT CONNECTION 3011. SET POINT CONNECTION There can 2, 3 or 4 set point output depend by SPEC. It need an external voltage (5 ~ 29

Page 27

DI 80 SET POINT CONNECTION 3111.3 SET POINT SET UP Below is a chart that show when the LEDs will be light up in latch and no

Page 28

DI 80 SELF TEST 32 12. SELF TEST There are 7 self test available for DI-80: a) RS 232 test b) RS 232 (optional board) test c) RS 485 (optio

Page 29

DI 80 CIRCUIT DIAGRAM 33 13. CIRCUIT DIAGRAM 13.1 DI 80 BLOCK DIAGRAM

Page 30

DI 80 CIRCUIT DIAGRAM 34 13.2 DI 80 MAIN BOARD TWB-02300-0 ( 1 of 4 )

Page 31 - *NABCDEFGH*

DI 80 CIRCUIT DIAGRAM 35 13.2 DI 80 MAIN BOARD TWB-02300-0 ( 2 OF 4 )

Page 32

DI 80 CIRCUIT DIAGRAM 36 13.2 DI 80 MAIN BOARD TWB-02300-0 ( 3 of 4 )

Page 33 - NO

DI 80 CIRCUIT DIAGRAM 37 13.2 DI 80 MAIN BOARD TWB-0230-0 ( 4 of 4 )

Page 34 - 8

DI 80 OVERALL DIMENSION 22. OVERALL DIMENSION

Page 35

DI 80 CIRCUIT DIAGRAM 38 13.3 DI 80 A/D BOARD TWB-02330-0

Page 36

DI 80 CIRCUIT DIAGRAM 39 13.4 DI 80 A/D FILTER BOARD TWB-02290-0

Page 37

DI 80 CIRCUIT DIAGRAM 40 13.5 DI 80 A/D CONNECTOR BOARD TWB-02360-0

Page 38

DI 80 CIRCUIT DIAGRAM 41 13.6 DI 80 KEY BOARD TWB-02380-0

Page 39

DI 80 CIRCUIT DIAGRAM 42 13.7 DI 80 CONNECTOR BOARD TWB-02310-0

Page 40

DI 80 CIRCUIT DIAGRAM 43 13.8a DI 80 OPTION BOARD 1 – PRINTER BOARD TWB-02340-0

Page 41

DI 80 CIRCUIT DIAGRAM 44 13.8b DI 80 OPTION BOARD 2 – RS232C / RS485 I NTERFACE BOARD TWB-02350-0

Page 42

DI 80 CIRCUIT DIAGRAM 45 13.8c DI 80 OPTION BOARD 3 – ANALOG INTERFACE BOARD TWB-02370-0

Page 43

DI 80 ANALOG OUTPUT BOARD CALIBRATION 46 14. ANALOG INTERFACE BOARD 14.1 SPECIFICATION This option board is used to transmit the analog weight

Page 44

DI 80 ANALOG OUTPUT BOARD CALIBRATION 47 2. Voltage Output Mode: 0 ~ 5V 3. Voltage Output Mode: 0 ~ 10V

Page 45

DI 80 DISPLAY LAYOUT 33. DISPLAY LAYOUT Segment Name Label Functions à0ß - ON when Net weight is zero B/G - ON when displaying gross we

Page 46

DI 80 ANALOG OUTPUT BOARD CALIBRATION 48 14.2 PIN CONFIGURATION PIN SIGNAL REMARKS PLUG WIRE COLOR 1 CO+ Current Output + RED 2 CO- Cu

Page 47 - DI 80 CIRCUIT DIAGRAM

DI 80 ANALOG OUTPUT BOARD CALIBRATION 49 14.4 CALIBRATION PROCEDURE Analog output value should be 4mA at Zero Point and 20mA at Capacity Weight

Page 48

1DI-80 Limited WarrantyRice Lake Weighing Systems (RLWS) warrants that all RLWS equipment and systems properly installed by aDistributor or Original E

Page 49

DI 80 KEYSHEET LAYOUT 4 4. KEYSHEET LAYOUT Key Name Weighing / Counting mode Self Test Calibration SPEC141 / SPEC142 PROG Mode ON/OFF

Page 50

DI 80 KEYSHEET LAYOUT 5 Key Name Weighing / Counting mode Self Test Calibration SPEC141 / SPEC142 PROG Mode Reduction Select type of self te

Page 51

DI 80 INITIAL SETUP 65. INITIAL SET UP 5.1 LOCATION OF CONNECTOR AND SWITCH Back of DI 80 5.2 MEMORY C

Page 52 - DI-80 Limited Warranty

DI 80 SOFTWARE SETTING 76. SOFTWARE SETTING 6.1 CUSTOMER SPEC SETTING OPERATION DISPLAY REMARKS Main(W) Sub-1(UW) Sub-2(Q) 0.000

Comments to this Manuals

No comments