After-sale service
86
Repair parts
Therepairpartsofthiswatchwillberetainedusuallyfor7years.
Somealternativepartsmaybeusedforrepairifnecessary.
Notes on overhaul
Periodic inspectionandadjustment bydisassembly and cleaning(overhaul)is
recommendedapproximatelyonceevery3to4yearsinordertomaintainoptimal
performanceofthewatchfora longtime. According to useconditions,the oil
retaining condition of your watchmechanical parts may deteriorate, abrasion
ofthepartsmay occur due to contamination ofoil,whichmay ultimately lead
the watchitself to stop. Asthepartssuchasgasketmay deteriorate, water-
resistant performance may be impaired due tointrusion of perspirationand
moisture.Please contact theretailer from whom the watch was purchased
for inspection and adjustment by disassembly and cleaning (overhaul). For
replacementofparts,pleasespecify"SEIKOGENUINEPARTS."Whenaskingfor
inspection and adjustment by disassemblyandcleaning (overhaul), make sure
thatthegasketandpushpinarealsoreplacedwithnewones.
Notes on guarantee and repair
Contact the retailer the watch was purchased from or SEIKO CUSTOMER
SERVICECENTERforrepairoroverhaul.
Withinthe guarantee period,presentthe certificateof guaranteeto receive
repairservices.
Guaranteecoverageisprovidedinthecerticateofguarantee.Readcarefully
andretainit.
89
Solution Reference
   Rechargethewatch.
Howtocharge
thewatchp.56
   
Returnthewatchtoanormaltemperaturesothatitworksaccuratelyasusual,andthenresetthetime.Thewatchhasbeen
adjustedsothatitworksaccuratelywhenitiswornonyourwristunderanormaltemperaturerangebetween5℃and35℃ .
Howtosetthe
timep.62
   
Correctthis condition bymoving and keeping thewatchaway fromthe magneticsource. If this
actiondoesnotcorrectthecondition,contacttheretailerfromwhomthewatchwaspurchased.
   
Resetthetime. If the watch doesnotreturn to its normal accuracy after
resettingthetime,contacttheretailerfromwhomthewatchwaspurchased.
   Contacttheretailerfromwhomthewatchwaspurchased.
   
Advancethehourhandsfor12hourstocorrectlysetthetime.
Howtosetthe
timep.62
88
Trouble Possiblecause
The watch stops operating
Thepowerreservehasbeenconsumed.
After charging the watch, the second hand
starts moving at 2-second intervals.
Thevoltageofthepowergeneratorhasbeendepleted.
The watch temporarily gains or
loses time.
Thewatchhasbeenleftinextremelyhighorlow
temperatures.
Thewatchhasbeenleftclosetoanobjectwitha
strongmagneticeld.
Youdropthewatch,hititagainstahardsurface,orwearitwhile
playingactivesports.Thewatchisexposedtostrongvibrations.
The inner surface of the glass is
clouded.
Moisturehasenteredthewatchbecausethegasket
hasdeteriorated.
The date changes during daytime.
AM/PMisnotcorrectlyset.
Troubleshooting
※Intheeventofanyotherproblem,pleasecontacttheretailerfromwhomthewatchwaspurchased.
91
Push the crown back in to the normal position.
TheDirectDriveindicatorhandpointsat0,andthewatchresumesitsnormaloperation.
※
Byconductingthisoperation,theDirectDriveindicatorhandmovestopointat0.
Thisisnotamalfunction.
※
Afterpushing thecrownback in to thenormalposition,ifnofurther power is
generatedsubsequently,thewatchwillstopoperatingwithinthreeminutes.
※
Thesecondhandmaymoveat2-secondintervals(2divisionsforwardatevery2
seconds).Insuchacase,theDirectDriveindicatorhandmaynotpointat0.
Turn the crown repeatedly in the direction shown by the arrow to charge the watch.
●
Continue to charge the watch until the amount of power
reservereachesatleast6hours.Afterthat,setthetime.
※RefertoHowtochargethewatchp.56
※RefertoHowtosetthetime”p.62
※
Ifthewatchdoesnotresumenormaloperationevenafterresettingthe
built-inIC,consulttheretailerfromwhomthewatchwaspurchased.
3
4
0 1  2
90
Improper function
How to reset the Built-in IC
When the watch stops operating even though its Direct Drive indicator hand displays the residual power
reserve, follow the instructions below to reset the Built-in IC. The watch will resume its normal operation.
Pull out the crown to the second click.
Press the button for 3 seconds or more using
a sharp-pointed tool (e.g. ball point pen).
※Ifyourwatchhasascrewlocktypecrown,unlockthe
crownrst,andthenpullthecrownout.
Thesecondhandstops.
1
2
0 1  2
Press for 3 seconds or more
92
1.Frequencyofcrystaloscillator・・・・ 32,768Hz(Hz=Hertz…Cyclespersecond)
2.Loss/gain(monthlyrate)・・・・・・・・・・ Lessthan15seconds(wornonthewristatnormaltemperaturerange
5℃〜 35 )
3.Operationaltemperaturerange ・・・
10℃〜 +60℃
4.Drivingsystem・・・・・・・・・・・・・・・・・・・・ Stepmotor:2pieces
5.Displayfunction・・・・・・・・・・・・・・・・・・・ Hour,minute,second,date,anddayoftheweek *
Power reser ve display (normal display), power generation status
display,andgeneratedpoweramountdisplay
※Somemodelsmaynothavethedayoftheweekdisplay.
6.Powersource・・・・・・・・・・・・・・・・・・・・・・ KINETICE.S.U.
7.Continuousoperatingtime・・・・・・・・ fromfullchargetostoppage:approximately30days
8.Additionalfunction・・・・・・・・・・・・・・・・ Overchargepreventionfunction
9.IC(IntegratedCircuit)・・・・・・・・・・・・・ Oscillator,frequencydivider,drivingandchargecontrolcircuit(C-MOS-
IC):1piece
10.Generatingsystem・・・・・・・・・・・・・・・ MiniatureAC generator (automatic generatingsystem with manual
windingfunction)
Thespecificationsaresubjecttochangewithoutpriornoticeforproductimprovements.
Specications
100-0005
東京都千代田区丸の内 3-1-1 国際
550-0013
大阪市西区新町 1-4-24 大阪四ツ橋新町
本社 〒
105-8467
東京都港区芝浦 1-2-1
http://www.seiko-watch.co.jp/
お客様相談室
全国共通
0120-612-911
Page view 11
1 2 ... 7 8 9 10 11 12

Comments to this Manuals

No comments