87
After-sale service
86
● Repair parts
・Therepairpartsofthiswatchwillberetainedusuallyfor7years.
・Somealternativepartsmaybeusedforrepairifnecessary.
● Notes on overhaul
・
Periodic inspectionandadjustment bydisassembly and cleaning(overhaul)is
recommendedapproximatelyonceevery3to4yearsinordertomaintainoptimal
performanceofthewatchfora longtime. According to useconditions,the oil
retaining condition of your watchmechanical parts may deteriorate, abrasion
ofthepartsmay occur due to contamination ofoil,whichmay ultimately lead
the watchitself to stop. Asthepartssuchasgasketmay deteriorate, water-
resistant performance may be impaired due tointrusion of perspirationand
moisture.Please contact theretailer from whom the watch was purchased
for inspection and adjustment by disassembly and cleaning (overhaul). For
replacementofparts,pleasespecify"SEIKOGENUINEPARTS."Whenaskingfor
inspection and adjustment by disassemblyandcleaning (overhaul), make sure
thatthegasketandpushpinarealsoreplacedwithnewones.
● Notes on guarantee and repair
・Contact the retailer the watch was purchased from or SEIKO CUSTOMER
SERVICECENTERforrepairoroverhaul.
・Withinthe guarantee period,presentthe certificateof guaranteeto receive
repairservices.
・Guaranteecoverageisprovidedinthecerticateofguarantee.Readcarefully
andretainit.
89
Solution Reference
Rechargethewatch.
Howtocharge
thewatchp.56
Returnthewatchtoanormaltemperaturesothatitworksaccuratelyasusual,andthenresetthetime.Thewatchhasbeen
adjustedsothatitworksaccuratelywhenitiswornonyourwristunderanormaltemperaturerangebetween5℃and35℃ .
Howtosetthe
timep.62
Correctthis condition bymoving and keeping thewatchaway fromthe magneticsource. If this
actiondoesnotcorrectthecondition,contacttheretailerfromwhomthewatchwaspurchased.
Resetthetime. If the watch doesnotreturn to its normal accuracy after
resettingthetime,contacttheretailerfromwhomthewatchwaspurchased.
Contacttheretailerfromwhomthewatchwaspurchased.
-
Advancethehourhandsfor12hourstocorrectlysetthetime.
Howtosetthe
timep.62
88
Trouble Possiblecause
The watch stops operating
Thepowerreservehasbeenconsumed.
After charging the watch, the second hand
starts moving at 2-second intervals.
Thevoltageofthepowergeneratorhasbeendepleted.
The watch temporarily gains or
loses time.
Thewatchhasbeenleftinextremelyhighorlow
temperatures.
Thewatchhasbeenleftclosetoanobjectwitha
strongmagneticeld.
Youdropthewatch,hititagainstahardsurface,orwearitwhile
playingactivesports.Thewatchisexposedtostrongvibrations.
The inner surface of the glass is
clouded.
Moisturehasenteredthewatchbecausethegasket
hasdeteriorated.
The date changes during daytime.
AM/PMisnotcorrectlyset.
Troubleshooting
※Intheeventofanyotherproblem,pleasecontacttheretailerfromwhomthewatchwaspurchased.
91
Push the crown back in to the normal position.
●
TheDirectDriveindicatorhandpointsat0,andthewatchresumesitsnormaloperation.
※
Byconductingthisoperation,theDirectDriveindicatorhandmovestopointat0.
Thisisnotamalfunction.
※
Afterpushing thecrownback in to thenormalposition,ifnofurther power is
generatedsubsequently,thewatchwillstopoperatingwithinthreeminutes.
※
Thesecondhandmaymoveat2-secondintervals(2divisionsforwardatevery2
seconds).Insuchacase,theDirectDriveindicatorhandmaynotpointat0.
Turn the crown repeatedly in the direction shown by the arrow to charge the watch.
●
Continue to charge the watch until the amount of power
reservereachesatleast6hours.Afterthat,setthetime.
※Referto“Howtochargethewatch”p.56
※Referto“Howtosetthetime”p.62
※
Ifthewatchdoesnotresumenormaloperationevenafterresettingthe
built-inIC,consulttheretailerfromwhomthewatchwaspurchased.
3
4
0 1 2
90
Improper function
■ How to reset the Built-in IC
When the watch stops operating even though its Direct Drive indicator hand displays the residual power
reserve, follow the instructions below to reset the Built-in IC. The watch will resume its normal operation.
Pull out the crown to the second click.
Press the button for 3 seconds or more using
a sharp-pointed tool (e.g. ball point pen).
※Ifyourwatchhasascrewlocktypecrown,unlockthe
crownrst,andthenpullthecrownout.
●Thesecondhandstops.
1
2
0 1 2
Press for 3 seconds or more
92
1.Frequencyofcrystaloscillator・・・・ 32,768Hz(Hz=Hertz…Cyclespersecond)
2.Loss/gain(monthlyrate)・・・・・・・・・・ Lessthan15seconds(wornonthewristatnormaltemperaturerange
5℃〜 35℃ )
3.Operationaltemperaturerange ・・・
–10℃〜 +60℃
4.Drivingsystem・・・・・・・・・・・・・・・・・・・・ Stepmotor:2pieces
5.Displayfunction・・・・・・・・・・・・・・・・・・・ Hour,minute,second,date,anddayoftheweek *
Power reser ve display (normal display), power generation status
display,andgeneratedpoweramountdisplay
※Somemodelsmaynothavethedayoftheweekdisplay.
6.Powersource・・・・・・・・・・・・・・・・・・・・・・ KINETICE.S.U.
7.Continuousoperatingtime・・・・・・・・ fromfullchargetostoppage:approximately30days
8.Additionalfunction・・・・・・・・・・・・・・・・ Overchargepreventionfunction
9.IC(IntegratedCircuit)・・・・・・・・・・・・・ Oscillator,frequencydivider,drivingandchargecontrolcircuit(C-MOS-
IC):1piece
10.Generatingsystem・・・・・・・・・・・・・・・ MiniatureAC generator (automatic generatingsystem with manual
windingfunction)
※
Thespecificationsaresubjecttochangewithoutpriornoticeforproductimprovements.
Specications
〒
100-0005
東京都千代田区丸の内 3-1-1 国際ビル
〒
550-0013
大阪市西区新町 1-4-24 大阪四ツ橋新町ビルディング
本社 〒
105-8467
東京都港区芝浦 1-2-1
http://www.seiko-watch.co.jp/
お客様相談室
全国共通フリーダイヤル
0120-612-911