Page view 110
Rev. D Notices for Replacement of the TM-U210/TM-U300 6-5
TM-U220 Technical Reference Guide
6.1.4.2 Effect on the application in the condition of release full state
The time from buffer full to releasing full state becomes longer than for the TM-U210. There is a
possibility that the application gets a time-out. For countermeasure, Memory switch
[MemSW8-7] assigned for selection of buffer-full release condition, 256 bytes (default) of 138
bytes. Therefore when the time-out occurs, set the memory switch [MemSW8-7] on.
6.1.5 Accessories compatibility
TM-U220 can use same consumables as the TM-U210. However, the power supply unit isn’t
compatible. The following sections describe these.
6.1.5.1 Power supply unit
The TM-U220 can’t use the power supply unit of TM-U210 (PA-#### or PB-####.) The TM-U220
can use the power supply units only as described in the following table.
CAUTION:
Don’t use the PA-#### or PB-#### power supply unit with TM-U220. Connection to an
improper power source may cause fire or shock.
6.1.5.2 Consumable compatibility
TM-U220 can use same consumables as the TM-U210 except the carbon roll paper (original + 2
copies. TM-U220 can’t print on carbon roll paper with 2 copies.)
6.1.6 Provided statuses
TM-U220 has same statuses as TM-U210; in addition, the TM-U220 has the following status
added. About the purpose of these, See “5.1 Various Status Categories (5-1 page).”
Roll paper cover open/close status (and detector)
When you replace the TM-U210 with the TM-U220, you have to set the Memory switch as
described below. These settings make the TM-U220 have almost the same as behavior as the
TM-U210 statuses.
Msw 8-5 “Cover open status mapping“ : OFF
( Default: Paper end status)
Msw 8-8 “Error select when cover is opened during printing“: OFF
(Default: Auto recover error)
TM-U220 ANK model (Type A,B, D) TM-U220 Multilingual model (Type A,B, D)
AC Adapter C (which is packed with ANK model)
or PS-180 (Which is provided as option)
PS-180 (which is packed with Multilingual model)
Consumables TM-U210 (Type A,B,D) TM-U220 (Type A,B, D)
Ribbon cassette ERC-38 (B), (P), (B/R) ERC-38 (B), (P), (B/R)
Page view 110