ADJUSTMENT Adjustments 205
3. Before moving the Adjust lever, remove the Ink cartridges, loosen the two screws
that secure the I/C spring and Head fastener, and remove the Torsion spring on the
left of the CR.
Figure 5-17. Head Fastener Fixing Screws and Torsion Spring
4. Refer to Figure 5-16 and move the Adjust lever, and while pressing both ends of
the Head fastener against the far side of the CR, tighten the fixing screws.
Figure 5-18. Head Fastener Fixing Method
5. Fit the Ink cartridges, print the Head tilt adjustment pattern, and check the
adjustment result.
6. Execute Steps 1 to 5 until the black and light magenta rules are at uniform
intervals.
Torsion spring
Head fastener
left fixing screw
I/C spring
Head fastener
right fixing screw
C H E C K
P O I N T
When moving the Head angular adjust lever again after checking
the adjustment result, always remove the Ink cartridges, loosen
the Head fastener fixing screws, and then move the Adjust lever.