Seiko UC-2200 Service Manual Page 98

  • Download
  • Add to my manuals
  • Print
  • Page
    / 258
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 97
EPSON Stylus PHOTO 2100/2200 Revision B
TROUBLESHOOTING Troubleshooting 98
At power-on At power-on, the ASF unit does
not operate at all.
ASF motor 1. Check that the ASF motor connector cable is connected to CN8
on the Main board correctly.
2. Using a tester, check that the resistance of the ASF motor is
7.0Ω ± 10%. (Across Pins 1 and 3 and across Pins 2 and 4,
respectively)
3. Check the ASF motor connector cable for damage.
1. Connect the ASF motor connector cable to
CN8 on the Main board correctly.
2. If the resistance value is abnormal, change the
ASF motor for a new one.
3. Change the ASF motor for a new one.
At power-on, the ASF unit does
not operate at all.
Extension spring
0.618
1. Check that the Extension spring 0.618 is mounted between the
DE lock lever and DE unit.
2. Check the Extension spring 0.618 for damage.
1. Install the Extension spring 0.618 between the
DE lock lever and DE unit.
2. Change the Extension spring 0.618 for a new
one.
Table 3-17. Phenomenon-Based Fatal Error Check Points
Occurrence Timing Phenomenon Detail
Faulty Part/Part
Name
Check Point Remedy
ASF motor
Left rear side
Extension spring 0.618
DE lock lever
Page view 97