TROUBLESHOOTING Troubleshooting 96
Table 3-17. Phenomenon-Based Fatal Error Check Points
Occurrence Timing Phenomenon Detail
Faulty Part/Part
Name
Check Point Remedy
At power-on At power-on, the CR motor does
not operate at all.
CR motor 1. Check that the CR motor connector cable is connected to CN17
on the Main board correctly.
2. Using a tester, check that the resistance of the CR motor is
23.0Ω ± 5%.
3. Check the CR motor connector cable for damage.
1. Connect the CR motor connector cable to
CN17 on the Main board correctly.
2. If the resistance value is abnormal, change the
CR motor for a new one.
3. Change the CR motor for a new one.
The power-on sequence is
executed but Fatal error is
displayed.
CR drive system 1. Check that the oil of the Oil pad in the CR unit and the grease of
the Carriage shaft B are sufficient.
2. Check 6C<H> and 6D<H> of the EEPROM to confirm that 14 is
at 6C<H> and 05 is at 6D<H>.
1. Wipe the surfaces of the CR guide shafts A
and B with a dry, soft cloth, and lubricate a
new oil pad with O-12 and the Carriage shaft
B with grease G-56.
2. If the values are as in Check point 2, change
the CR motor for a new one. Alternatively,
lubricate as described in above 1 since the CR
drive system is overloaded.
CR motor
Oil pad
Carriage unit bottom
Carriage shaft B